Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Measurable parameters for performance of correded and repaired RC beams under load

Includes abstract.

Saved in:
Bibliographic Details
Main Author: Malumbela, Goitseone
Other Authors: Alexander, Mark Gavin
Format: Thesis
Language:English
Published: Department of Civil Engineering 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614191372730368
access_status_str Open Access
author Malumbela, Goitseone
author2 Alexander, Mark Gavin
author_browse Alexander, Mark Gavin
Malumbela, Goitseone
author_facet Alexander, Mark Gavin
Malumbela, Goitseone
author_sort Malumbela, Goitseone
collection Thesis
description Includes abstract.
format Thesis
id oai:open.uct.ac.za:11427/11419
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:48:07.267Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2015
publishDateRange 2015
publishDateSort 2015
publisher Department of Civil Engineering
publisherStr Department of Civil Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/11419 Measurable parameters for performance of correded and repaired RC beams under load Malumbela, Goitseone Alexander, Mark Gavin Moyo, Pilate Civil Engineering Includes abstract. Includes bibliographical references. Structural engineers and asset managers rely on measurable parameters developed by researchers to predict residual load-bearing capacities of corroding in-service RC structures and to assess repair-effectiveness. Laboratory research that was used to develop these measurable parameters varied between researchers and in most cases, did not represent in-service conditions. As a result, they found different relations between measurable and non-measurable parameters which are unsafe and/or engineers find difficult to apply to in-service structures. A holistic research that emulates in-service conditions was therefore developed. Parameters that were looked at were corrosion crack widths and longitudinal strains together with their derivatives. 2015-01-05T18:19:36Z 2015-01-05T18:19:36Z 2010 Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/11419 eng application/pdf Department of Civil Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Civil Engineering
Malumbela, Goitseone
Measurable parameters for performance of correded and repaired RC beams under load
thesis_degree_str Doctoral
title Measurable parameters for performance of correded and repaired RC beams under load
title_full Measurable parameters for performance of correded and repaired RC beams under load
title_fullStr Measurable parameters for performance of correded and repaired RC beams under load
title_full_unstemmed Measurable parameters for performance of correded and repaired RC beams under load
title_short Measurable parameters for performance of correded and repaired RC beams under load
title_sort measurable parameters for performance of correded and repaired rc beams under load
topic Civil Engineering
url http://hdl.handle.net/11427/11419
work_keys_str_mv AT malumbelagoitseone measurableparametersforperformanceofcorrededandrepairedrcbeamsunderload