Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality

Electrical Impedance Tomography (EIT) is a noninvasive imaging technique that reproduces images of cross-sections, based on the internal impedance distribution of an object. This Dissertation investigates and confirms the use of a dual current stimulation EIT (DCS EIT) system. The results of this in...

Full description

Saved in:
Bibliographic Details
Main Author: America, Ezra Luke
Other Authors: Tšoeu, Mohohlo
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2019
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613282740731904
access_status_str Open Access
author America, Ezra Luke
author2 Tšoeu, Mohohlo
author_browse America, Ezra Luke
Tšoeu, Mohohlo
author_facet Tšoeu, Mohohlo
America, Ezra Luke
author_sort America, Ezra Luke
collection Thesis
description Electrical Impedance Tomography (EIT) is a noninvasive imaging technique that reproduces images of cross-sections, based on the internal impedance distribution of an object. This Dissertation investigates and confirms the use of a dual current stimulation EIT (DCS EIT) system. The results of this investigation presented a size error of 2.82 % and a position error of 5.93 % in the reconstructed images, when compared to the actual size and position of the anomaly inside a test object. These results confirmed that the DCS EIT system produced images of superior quality (fewer image reconstruction errors) to those produced from reviewed single plane stimulating EIT systems, which confirmed the research hypothesis. This system incorporates two independent current stimulating patterns, which establishes a more even distribution of current in the test object, compared to single plane systems, and is more efficient than 2.5D EIT systems because the DCS EIT system only measures boundary voltages in the center plane, compared to 2.5D EIT systems that measure the boundary voltages in all electrode planes. The system uses 48 compound electrodes, divided into three electrode planes. Current is sourced and sunk perpendicularly in the center plane, to produce a high current density near the center of the test object. Sequentially, current is sourced through an electrode in the top electrode plane and sunk through an electrode in the bottom plane, directly below the source electrode, to produce a high current density near the boundary of the test object, in the center plane. During both injection cycles, boundary potentials are measured in the center plane. Following the measurement of a complete frame, a weighted average is computed from the single and cross plane measured data. The weighted measured voltages, injected currents and Finite Element Model of the object is used to reconstruct an image of the internal impedance distribution along a cross-section of the object. This method is applicable to the biomedical imaging and process monitoring fields.
format Thesis
id oai:open.uct.ac.za:11427/29402
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:33:40.116Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2019
publishDateRange 2019
publishDateSort 2019
publisher Department of Electrical Engineering
publisherStr Department of Electrical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/29402 Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality America, Ezra Luke Tšoeu, Mohohlo Engineering Electrical Impedance Tomography (EIT) is a noninvasive imaging technique that reproduces images of cross-sections, based on the internal impedance distribution of an object. This Dissertation investigates and confirms the use of a dual current stimulation EIT (DCS EIT) system. The results of this investigation presented a size error of 2.82 % and a position error of 5.93 % in the reconstructed images, when compared to the actual size and position of the anomaly inside a test object. These results confirmed that the DCS EIT system produced images of superior quality (fewer image reconstruction errors) to those produced from reviewed single plane stimulating EIT systems, which confirmed the research hypothesis. This system incorporates two independent current stimulating patterns, which establishes a more even distribution of current in the test object, compared to single plane systems, and is more efficient than 2.5D EIT systems because the DCS EIT system only measures boundary voltages in the center plane, compared to 2.5D EIT systems that measure the boundary voltages in all electrode planes. The system uses 48 compound electrodes, divided into three electrode planes. Current is sourced and sunk perpendicularly in the center plane, to produce a high current density near the center of the test object. Sequentially, current is sourced through an electrode in the top electrode plane and sunk through an electrode in the bottom plane, directly below the source electrode, to produce a high current density near the boundary of the test object, in the center plane. During both injection cycles, boundary potentials are measured in the center plane. Following the measurement of a complete frame, a weighted average is computed from the single and cross plane measured data. The weighted measured voltages, injected currents and Finite Element Model of the object is used to reconstruct an image of the internal impedance distribution along a cross-section of the object. This method is applicable to the biomedical imaging and process monitoring fields. 2019-02-07T08:41:15Z 2019-02-07T08:41:15Z 2018 2019-02-07T08:40:08Z Master Thesis Masters MSc http://hdl.handle.net/11427/29402 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Engineering
America, Ezra Luke
Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
thesis_degree_str Master's
title Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
title_full Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
title_fullStr Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
title_full_unstemmed Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
title_short Electrical Impedance Tomography (EIT): The Establishment of a Dual Current Stimulation EIT System for Improved Image Quality
title_sort electrical impedance tomography eit the establishment of a dual current stimulation eit system for improved image quality
topic Engineering
url http://hdl.handle.net/11427/29402
work_keys_str_mv AT americaezraluke electricalimpedancetomographyeittheestablishmentofadualcurrentstimulationeitsystemforimprovedimagequality