Magnetic Resonance Imaging (MRI) is remarkable in that it is possible to obtain image resolutions much smaller than the wavelength of the radiated signal. This is achieved through the use of specialised gradient coils that linearly manipulate the magnitude of the magnetic field within the imaging vo...

Full description

Saved in:
Bibliographic Details
Main Author: Van Niekerk, Adam Marthinus Johannes
Other Authors: Meintjes, Ernesta
Format: Thesis
Language:English
Published: Department of Human Biology 2019
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613199231090688
access_status_str Open Access
author Van Niekerk, Adam Marthinus Johannes
author2 Meintjes, Ernesta
author_browse Meintjes, Ernesta
Van Niekerk, Adam Marthinus Johannes
author_facet Meintjes, Ernesta
Van Niekerk, Adam Marthinus Johannes
author_sort Van Niekerk, Adam Marthinus Johannes
collection Thesis
description Magnetic Resonance Imaging (MRI) is remarkable in that it is possible to obtain image resolutions much smaller than the wavelength of the radiated signal. This is achieved through the use of specialised gradient coils that linearly manipulate the magnitude of the magnetic field within the imaging volume. The instantaneous signal received from the subject represents a periodically varying map based on the duration and magnitude (moment) of the previously applied gradient fields. Representing an object as the sum of periodic maps is difficult and as a result many unique gradient moments are required to form an image. When the subject moves the periodic maps are no longer coherent and the constructive/destructive interference becomes invalid. The artefacts are dependent on how and when motion occurred, and manifest as ghosting, ringing and blurring of the image. This thesis describes a novel approach to measuring and correcting for motion as the data are acquired. A small device was constructed that combines observations from a magnetometer (static magnetic field [z]) and an accelerometer (earth’s gravitational field [y]) with an angular rate sensor to determine its orientation with respect to the imaging coordinate frame (VectOrient). It was precise enough to track the subject’s heart beat and breathing and accurate to within one degree. A gradient field probe was then designed for position encoding. The probe measured the rate of change of the gradient magnetic fields using three mutually orthogonal pickup coils. Assuming linear gradients and using Maxwell’s equations, with negligible rates of change of curl and divergence, it was possible to accurately model the three dimensional vector fields that the gradients produce, eliminating the need for a laborious manual calibration. Sub-microsecond synchronisation was achieved by detecting radio frequency pulses in the imaging sequence with a small resonant circuit. This combined with a 2.4 GHz radio link enabled the probe to be wireless. Finally, the pickup coil observations were combined with the vector based orientation estimates and the gradient field model to achieve efficient multidimensional position, orientation and inter-gradient-delay encoding with a 880 µs pulse sequence insert. The Wireless Radio frequency triggered Acquisition Device (WRAD) tracks involuntary and deliberate subject motion, improving image quality without scanner specific calibration.
format Thesis
id oai:open.uct.ac.za:11427/30093
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:32:20.328Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2019
publishDateRange 2019
publishDateSort 2019
publisher Department of Human Biology
publisherStr Department of Human Biology
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/30093 A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI) Van Niekerk, Adam Marthinus Johannes Meintjes, Ernesta van der Kouwe, Andre Magnetic Resonance Imaging (MRI) is remarkable in that it is possible to obtain image resolutions much smaller than the wavelength of the radiated signal. This is achieved through the use of specialised gradient coils that linearly manipulate the magnitude of the magnetic field within the imaging volume. The instantaneous signal received from the subject represents a periodically varying map based on the duration and magnitude (moment) of the previously applied gradient fields. Representing an object as the sum of periodic maps is difficult and as a result many unique gradient moments are required to form an image. When the subject moves the periodic maps are no longer coherent and the constructive/destructive interference becomes invalid. The artefacts are dependent on how and when motion occurred, and manifest as ghosting, ringing and blurring of the image. This thesis describes a novel approach to measuring and correcting for motion as the data are acquired. A small device was constructed that combines observations from a magnetometer (static magnetic field [z]) and an accelerometer (earth’s gravitational field [y]) with an angular rate sensor to determine its orientation with respect to the imaging coordinate frame (VectOrient). It was precise enough to track the subject’s heart beat and breathing and accurate to within one degree. A gradient field probe was then designed for position encoding. The probe measured the rate of change of the gradient magnetic fields using three mutually orthogonal pickup coils. Assuming linear gradients and using Maxwell’s equations, with negligible rates of change of curl and divergence, it was possible to accurately model the three dimensional vector fields that the gradients produce, eliminating the need for a laborious manual calibration. Sub-microsecond synchronisation was achieved by detecting radio frequency pulses in the imaging sequence with a small resonant circuit. This combined with a 2.4 GHz radio link enabled the probe to be wireless. Finally, the pickup coil observations were combined with the vector based orientation estimates and the gradient field model to achieve efficient multidimensional position, orientation and inter-gradient-delay encoding with a 880 µs pulse sequence insert. The Wireless Radio frequency triggered Acquisition Device (WRAD) tracks involuntary and deliberate subject motion, improving image quality without scanner specific calibration. 2019-05-15T07:49:33Z 2019-05-15T07:49:33Z 2019 2019-05-14T07:12:42Z Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/30093 eng application/pdf Department of Human Biology Faculty of Health Sciences
spellingShingle Van Niekerk, Adam Marthinus Johannes
A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
thesis_degree_str Doctoral
title A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
title_full A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
title_fullStr A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
title_full_unstemmed A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
title_short A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
title_sort vector based approach for high frequency prospective correction of rigid body motion in magnetic resonance imaging mri
url http://hdl.handle.net/11427/30093
work_keys_str_mv AT vanniekerkadammarthinusjohannes avectorbasedapproachforhighfrequencyprospectivecorrectionofrigidbodymotioninmagneticresonanceimagingmri
AT vanniekerkadammarthinusjohannes vectorbasedapproachforhighfrequencyprospectivecorrectionofrigidbodymotioninmagneticresonanceimagingmri