Full Text Available
Note: Clicking the button above will open the full text document at the original institutional repository in a new window.
Background: Video laryngoscopy has directly impacted airway management, with numerous studies demonstrating its utility in clinical management of anatomically difficult airways. However, availability of video laryngoscopes in all clinical areas has been limited by cost. We used smartphone technology...
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | English |
| Published: |
Department of Anaesthesia and Perioperative Medicine
2022
|
| Subjects: | |
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867613169104453632 |
|---|---|
| access_status_str | Open Access |
| author | De Villiers, Christiaan Tertius |
| author2 | Hofmeyr, Ross |
| author_browse | De Villiers, Christiaan Tertius Hofmeyr, Ross |
| author_facet | Hofmeyr, Ross De Villiers, Christiaan Tertius |
| author_sort | De Villiers, Christiaan Tertius |
| collection | Thesis |
| description | Background: Video laryngoscopy has directly impacted airway management, with numerous studies demonstrating its utility in clinical management of anatomically difficult airways. However, availability of video laryngoscopes in all clinical areas has been limited by cost. We used smartphone technology, miniature cameras and three-dimensional printing to design and create an innovative low-cost hyperangulated video laryngoscope. This has the potential to make the technique more widely available. Objectives: The aim of this study was to determine if time to intubation with the novel device was clinically equivalent to an existing gold-standard video laryngoscope (Storz CMAC with Dörges blade). Methods: We conducted a randomised, controlled, cross-over equivalence study with 100 skilled practitioners who had previous video laryngoscopy experience. Participants received instruction on the new device, and adequate opportunity to practice. Intubations were then performed in a randomised order on a mannikin simulating a difficult airway. Video recordings of each intubation were analysed by two independent investigators to determine time to intubation. A mean difference in intubation time of less than 10 seconds was determined a priori to denote clinical equivalence. Results: Mean difference in intubation time between the devices was 4.92 seconds, (two one-sided test 95%CI: 2.34 – 7.49 seconds). The innovative low-cost VL was thus clinically equivalent to the industry standard in a simulated difficult airway. Further testing in vivo in a clinical environment is needed. Conclusion: The results of this study show that a low-cost disposable hyperangulated video laryngoscope is clinically equivalent to the industry standard in a simulated difficult airway. In the context of the current global pandemic, video laryngoscopy has been advised in nearly all airway guidelines. Access to a low-cost VL which does not require reprocessing may be of great value. |
| format | Thesis |
| id | oai:open.uct.ac.za:11427/35535 |
| institution | University of Cape Town (South Africa) |
| language | eng |
| last_indexed | 2026-06-10T12:31:52.071Z |
| license_str | Not specified — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository |
| publishDate | 2022 |
| publishDateRange | 2022 |
| publishDateSort | 2022 |
| publisher | Department of Anaesthesia and Perioperative Medicine |
| publisherStr | Department of Anaesthesia and Perioperative Medicine |
| record_format | dspace |
| source_str | UCTD — University of Cape Town Open Access Repository |
| spelling | oai:open.uct.ac.za:11427/35535 Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway De Villiers, Christiaan Tertius Hofmeyr, Ross Anaesthesia and Perioperative Medicine Background: Video laryngoscopy has directly impacted airway management, with numerous studies demonstrating its utility in clinical management of anatomically difficult airways. However, availability of video laryngoscopes in all clinical areas has been limited by cost. We used smartphone technology, miniature cameras and three-dimensional printing to design and create an innovative low-cost hyperangulated video laryngoscope. This has the potential to make the technique more widely available. Objectives: The aim of this study was to determine if time to intubation with the novel device was clinically equivalent to an existing gold-standard video laryngoscope (Storz CMAC with Dörges blade). Methods: We conducted a randomised, controlled, cross-over equivalence study with 100 skilled practitioners who had previous video laryngoscopy experience. Participants received instruction on the new device, and adequate opportunity to practice. Intubations were then performed in a randomised order on a mannikin simulating a difficult airway. Video recordings of each intubation were analysed by two independent investigators to determine time to intubation. A mean difference in intubation time of less than 10 seconds was determined a priori to denote clinical equivalence. Results: Mean difference in intubation time between the devices was 4.92 seconds, (two one-sided test 95%CI: 2.34 – 7.49 seconds). The innovative low-cost VL was thus clinically equivalent to the industry standard in a simulated difficult airway. Further testing in vivo in a clinical environment is needed. Conclusion: The results of this study show that a low-cost disposable hyperangulated video laryngoscope is clinically equivalent to the industry standard in a simulated difficult airway. In the context of the current global pandemic, video laryngoscopy has been advised in nearly all airway guidelines. Access to a low-cost VL which does not require reprocessing may be of great value. 2022-01-20T09:15:24Z 2022-01-20T09:15:24Z 2021 2022-01-18T11:13:30Z Master Thesis Masters MMed http://hdl.handle.net/11427/35535 eng application/pdf Department of Anaesthesia and Perioperative Medicine Faculty of Health Sciences |
| spellingShingle | Anaesthesia and Perioperative Medicine De Villiers, Christiaan Tertius Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| thesis_degree_str | Master's |
| title | Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| title_full | Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| title_fullStr | Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| title_full_unstemmed | Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| title_short | Innovation in low-cost video-laryngoscopy: Intubator V1-Indirect compared with Storz C-MAC in a simulated difficult airway |
| title_sort | innovation in low cost video laryngoscopy intubator v1 indirect compared with storz c mac in a simulated difficult airway |
| topic | Anaesthesia and Perioperative Medicine |
| url | http://hdl.handle.net/11427/35535 |
| work_keys_str_mv | AT devillierschristiaantertius innovationinlowcostvideolaryngoscopyintubatorv1indirectcomparedwithstorzcmacinasimulateddifficultairway |