Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.

The study ventures into the development of a micro-based doubly fed induction generator (DFIG) test rig for fault studies. The 5kW wound rotor induction machine (WRIM) that was used in the test rig was based on a scaled-down version of a 2.5MW doubly fed induction generator (DFIG). The micromachine...

Full description

Saved in:
Bibliographic Details
Main Author: Hamatwi, Ester
Other Authors: Barendse, Paul
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613165642055680
access_status_str Open Access
author Hamatwi, Ester
author2 Barendse, Paul
author_browse Barendse, Paul
Hamatwi, Ester
author_facet Barendse, Paul
Hamatwi, Ester
author_sort Hamatwi, Ester
collection Thesis
description The study ventures into the development of a micro-based doubly fed induction generator (DFIG) test rig for fault studies. The 5kW wound rotor induction machine (WRIM) that was used in the test rig was based on a scaled-down version of a 2.5MW doubly fed induction generator (DFIG). The micromachine has been customized to make provision for implementing stator inter-turn short-circuit faults (ITSCF), rotor ITSCF and static eccentricity (SE) faults in the laboratory environment. The micromachine has been assessed under the healthy and faulty states, both before and after incorporating a converter into the rotor circuit of the machine. In each scenario, the fault signatures have been characterised by analyzing the stator current, rotor current, and the DFIG controller signals using the motor current signature analysis (MCSA) and discrete wavelet transform (DWT) analysis techniques to detect the dominant frequency components which are indicative of these faults. The purpose of the study is to evaluate and identify the most suitable combination of signals and techniques for the detection of each fault under steady-state and transient operating conditions. The analyses of the results presented in this study have indicated that characterizing the fault indicators independent of the converter system ensured clarity in the fault diagnosis process and enabled the development of a systematic fault diagnosis approach that can be applied to a controlled DFIG. It has been demonstrated that the occurrence of the ITSCFs and the SE fault in the micro-WRIM intensifies specific frequency components in the spectral plots of the stator current, rotor current, and the DFIG controller signals, which may then serve as the dominant fault indicators. These dominant components may be used as fault markers for classification and have been used for pattern recognition under the transient condition. In this case, the DWT and spectrogram plots effectively illustrated characteristic patterns of the dominant fault indicators, which were observed to evolve uniquely and more distinguishable in the rotor current signal compared to the stator current signal, before incorporating the converter in the rotor circuit. Therefore, by observing the trends portrayed in the decomposition bands and the spectrogram plots, it is deemed a reliable method of diagnosing and possibly quantifying the intensity of the faults in the machine. Once the power electronic converter was incorporated into the rotor circuit, the DFIG controller signals have been observed to be best suited for diagnosing faults in the micro-DFIG under the steady-state operating condition, as opposed to using the terminal stator or rotor current signals. The study also assessed the impact of undervoltage conditions at the point of common coupling (PCC) on the behaviour of the micro-DFIG. In this investigation, a significant rise in the faulted currents was observed for the undervoltage condition in comparison to the faulty cases under the rated grid voltage conditions. In this regard, it could be detrimental to the operation of the micro-DFIG, particularly the faulted phase windings, and the power electronic converter, should the currents exceed the rated values for extended periods.
format Thesis
id oai:open.uct.ac.za:11427/38009
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:48.735Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2023
publishDateRange 2023
publishDateSort 2023
publisher Department of Electrical Engineering
publisherStr Department of Electrical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/38009 Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques. Hamatwi, Ester Barendse, Paul Electrical Engineering The study ventures into the development of a micro-based doubly fed induction generator (DFIG) test rig for fault studies. The 5kW wound rotor induction machine (WRIM) that was used in the test rig was based on a scaled-down version of a 2.5MW doubly fed induction generator (DFIG). The micromachine has been customized to make provision for implementing stator inter-turn short-circuit faults (ITSCF), rotor ITSCF and static eccentricity (SE) faults in the laboratory environment. The micromachine has been assessed under the healthy and faulty states, both before and after incorporating a converter into the rotor circuit of the machine. In each scenario, the fault signatures have been characterised by analyzing the stator current, rotor current, and the DFIG controller signals using the motor current signature analysis (MCSA) and discrete wavelet transform (DWT) analysis techniques to detect the dominant frequency components which are indicative of these faults. The purpose of the study is to evaluate and identify the most suitable combination of signals and techniques for the detection of each fault under steady-state and transient operating conditions. The analyses of the results presented in this study have indicated that characterizing the fault indicators independent of the converter system ensured clarity in the fault diagnosis process and enabled the development of a systematic fault diagnosis approach that can be applied to a controlled DFIG. It has been demonstrated that the occurrence of the ITSCFs and the SE fault in the micro-WRIM intensifies specific frequency components in the spectral plots of the stator current, rotor current, and the DFIG controller signals, which may then serve as the dominant fault indicators. These dominant components may be used as fault markers for classification and have been used for pattern recognition under the transient condition. In this case, the DWT and spectrogram plots effectively illustrated characteristic patterns of the dominant fault indicators, which were observed to evolve uniquely and more distinguishable in the rotor current signal compared to the stator current signal, before incorporating the converter in the rotor circuit. Therefore, by observing the trends portrayed in the decomposition bands and the spectrogram plots, it is deemed a reliable method of diagnosing and possibly quantifying the intensity of the faults in the machine. Once the power electronic converter was incorporated into the rotor circuit, the DFIG controller signals have been observed to be best suited for diagnosing faults in the micro-DFIG under the steady-state operating condition, as opposed to using the terminal stator or rotor current signals. The study also assessed the impact of undervoltage conditions at the point of common coupling (PCC) on the behaviour of the micro-DFIG. In this investigation, a significant rise in the faulted currents was observed for the undervoltage condition in comparison to the faulty cases under the rated grid voltage conditions. In this regard, it could be detrimental to the operation of the micro-DFIG, particularly the faulted phase windings, and the power electronic converter, should the currents exceed the rated values for extended periods. 2023-07-03T09:43:02Z 2023-07-03T09:43:02Z 2023 2023-07-03T09:41:23Z Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/38009 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment
spellingShingle Electrical Engineering
Hamatwi, Ester
Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
thesis_degree_str Doctoral
title Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
title_full Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
title_fullStr Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
title_full_unstemmed Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
title_short Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
title_sort detection of faults in a scaled down doubly fed induction generator using advanced signal processing techniques
topic Electrical Engineering
url http://hdl.handle.net/11427/38009
work_keys_str_mv AT hamatwiester detectionoffaultsinascaleddowndoublyfedinductiongeneratorusingadvancedsignalprocessingtechniques