Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

A Test and Characterisation Facility for Cryogenic Low Noise Amplifiers

This dissertation discusses how the receiver and the LNA contained within the receiver are the major contributors to the sensitivity. Furthermore, a method for testing and determining the equivalent noise temperature of a cryogenic LNA operating at a physical temperature of 20 K is selected and pres...

Full description

Saved in:
Bibliographic Details
Main Author: Newton, Wesley
Other Authors: Schonken, Willem
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This dissertation discusses how the receiver and the LNA contained within the receiver are the major contributors to the sensitivity. Furthermore, a method for testing and determining the equivalent noise temperature of a cryogenic LNA operating at a physical temperature of 20 K is selected and presented. This method was tested at the Klerefontein support base and the measurements allowed conclusions to be drawn that show that the uncertainty was unacceptable due to a few factors. One of the factors is the thermal gradient across the attenuator. This was investigated via a limited thermal study and a solution was proposed and implemented.