Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Prediction and measurement of the performance of bulk air coolers

Thesis (M. Eng. (Mechanical)) -- University of Stellenbosch, 1990.

Saved in:
Bibliographic Details
Main Author: Schultz, Torsten
Other Authors: Erens, P. J.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614116737187841
access_status_str Open Access
author Schultz, Torsten
author2 Erens, P. J.
author_browse Erens, P. J.
Schultz, Torsten
author_facet Erens, P. J.
Schultz, Torsten
author_sort Schultz, Torsten
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (M. Eng. (Mechanical)) -- University of Stellenbosch, 1990.
format Thesis
id oai:scholar.sun.ac.za:10019.1/68942
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:46:55.727Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/68942 Prediction and measurement of the performance of bulk air coolers Schultz, Torsten Erens, P. J. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Cooling towers -- Computer simulation Air flow -- Cooling -- Computer simulation Heat exchangers -- Cooling -- Computer simulation Dissertations -- Mechanical engineering Thesis (M. Eng. (Mechanical)) -- University of Stellenbosch, 1990. ENGLISH ABSTRACT: In this thesis various analytical models simulating direct contact counterflow air coolers and cooling towers have been developed. These models range from the simplified model based on the work by Merkel [26ME1] to the more comprehensive model based on the work by Poppe [84PO1]. Computer programs have been written to predict the performance as well as the outlet air and water conditions of bulk air coolers and cooling towers. Tests have been conducted on a direct contact counterflow tower operating in the air cooler and cooling tower mode to determine the transfer characteristic of splash and film type fill material. The temperature dependency of the transfer characteristic is examined and transfer characteristic correlations taking the temperature influence into account are presented. The droplet mass flow rate in the outlet air has been measured to determine the amount of drift and fog leaving a bulk air cooler. A simple correlation predicting the droplet mass flow rate below the drift eliminators is presented. It is concluded that the large amounts of water found in the outlet air of some bulk air coolers is mainly due to droplet carry-over rather that recondensation of moisture. AFRIKAANSE OPSOMMING: In heirdie tesis is verskillende analitiese modelle ontwikkel wat die werking van direkte kontak teenvloei lugverkoelers en koeltorings simuleer. Hierdie modelle strek vanaf die eenvoudige model gebaseer op die werk van Merkel [26ME1] tot die meer uitgebreide model gebaseer op die werk van Poppe [84PO1]. Verskye rekenaar programme is geskryf om die werkverrigting en die lug en water uitlaattoestande van lugverkoelers en koeltorings te voorspel. Eksperimente is op 'n direkte kontak teenvloei toring uitgevoer wat in beide die lugverkoeler en koeltoring mode bedryf word ten einde die oordragskarakteristieke van die spat- en film-tipe pakking te bepaal. Die temperatuurafhanklikheid van die oordragskarakteristieke is ondersoek en korrelasies van laasgenoemde wat die tempertatuurafhanklikheid in ag neem is voorgestel. Die druppel-massavloeitempo in die uitlaatlug is gemeet om die hoeveelheid sproeidruppels en herkondensasiedruppels wat 'n lugverkoeler verlaat te bepaal. verder word 'n eenvoudige korrelasie voorgestel wat die druppelmassavloeitempo onder die druppelskeiers voorspel. Die gevolgtrekking word gemaak dat die groot hoeveelhede water wat in die uitlaatlug van somminge lugverkoelers teenwoordig is, hoofsaaklik aan die sproeidruppel-oordrag eerder as herkondensasie van vog te wyte is. Masters 2012-08-27T12:26:50Z 2012-08-27T12:26:50Z 1990 Thesis http://hdl.handle.net/10019.1/68942 en_ZA Stellenbosch University 233 pages : ill. application/pdf Stellenbosch : Stellenbosch University
spellingShingle Cooling towers -- Computer simulation
Air flow -- Cooling -- Computer simulation
Heat exchangers -- Cooling -- Computer simulation
Dissertations -- Mechanical engineering
Schultz, Torsten
Prediction and measurement of the performance of bulk air coolers
title Prediction and measurement of the performance of bulk air coolers
title_full Prediction and measurement of the performance of bulk air coolers
title_fullStr Prediction and measurement of the performance of bulk air coolers
title_full_unstemmed Prediction and measurement of the performance of bulk air coolers
title_short Prediction and measurement of the performance of bulk air coolers
title_sort prediction and measurement of the performance of bulk air coolers
topic Cooling towers -- Computer simulation
Air flow -- Cooling -- Computer simulation
Heat exchangers -- Cooling -- Computer simulation
Dissertations -- Mechanical engineering
url http://hdl.handle.net/10019.1/68942
work_keys_str_mv AT schultztorsten predictionandmeasurementoftheperformanceofbulkaircoolers